FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource CodeSystem/FHIR Server from package hl7.terminology#current (47 ms)

Package hl7.terminology
Type CodeSystem
Id Id
FHIR Version R5
Source http://terminology.hl7.org/https://build.fhir.org/ig/HL7/UTG/CodeSystem-v2-0174.html
Url http://terminology.hl7.org/CodeSystem/v2-0174
Version 2.0.0
Status active
Date 2019-12-01
Name NatureOfServiceTestObservation
Title natureOfServiceTestObservation
Experimental False
Realm uv
Authority hl7
Description Code system of concepts specifying an identification of a test battery, an entire functional procedure or study, a single test value (observation), multiple test batteries or functional procedures as an orderable unit (profile), or a single test value (observation) calculated from other independent observations, typically used as an indicator for Master Files. Used in HL7 Version 2.x messaging in the OM1 segment.
Purpose Underlying Master Code System for V2 table 0174 (Nature of Service/Test/Observation)
Copyright This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html
Content complete
valueSet http://terminology.hl7.org/ValueSet/v2-0174

Resources that use this resource

ValueSet
v2-0174 hl7VS-natureOfServiceTestObservation

Resources that this resource uses

No resources found



Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: CodeSystem v2-0174

Properties

This code system defines the following properties for its concepts

NameCodeURITypeDescription
statusstatushttp://terminology.hl7.org/CodeSystem/utg-concept-properties#statuscodeStatus of the concept
deprecateddeprecatedhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecatedcodeVersion of HL7 in which the code was deprecated
V2 Concept Commentv2-concCommenthttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentstringV2 Concept Comment
V2 Concept Comment As Publishedv2-concCommentAsPubhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPubstringV2 Concept Comment As Published

Concepts

This case-sensitive code system http://terminology.hl7.org/CodeSystem/v2-0174 defines the following codes in a Is-A hierarchy:

CodeDisplayDefinitionV2 Concept CommentV2 Concept Comment As PublishedDeutsch (German, de)
P Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimen

Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimen

can be associated with one or more OM4 (specimen) segments<p>See comment for value Scan be associated with one or more OM4 (specimen) segments<p>See comment for value SBatterieanordnung
F Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens

Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens

can be associated with one or more OM4 (specimen) segments<p>See comment for value Scan be associated with one or more OM4 (specimen) segments<p>See comment for value SFunktionstest
A Atomic service/test/observation (test code or treatment code)

Atomic service/test/observation (test code or treatment code)

can be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segmentscan be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segmentsEinzeluntersuchung
S Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes)<p>This set indicates that the code being described is used to order multiple service/test/observation b

Superset—a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes) This set indicates that the code being described is used to order multiple service/test/observation batteries. For example, a client who routinely orders a CBC, a differential, and a thyroxine as an outpatient profile might use a single, special code to order all three test batteries, instead of having to submit three separate order codes.

can be associated with one or more OM4 (specimen) segments Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observationcan be associated with one or more OM4 (specimen) segments Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observationLatte von mehreren Batterieanforderungen (Aufnahmelatte)
C Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output)

Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output)

can be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segmentcan be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segmentBerechnetes Einzelergebnis

Source

{
  "resourceType" : "CodeSystem",
  "id" : "v2-0174",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CodeSystem v2-0174</b></p><a name=\"v2-0174\"> </a><a name=\"hcv2-0174\"> </a><a name=\"v2-0174-en-US\"> </a><p><b>Properties</b></p><p><b>This code system defines the following properties for its concepts</b></p><table class=\"grid\"><tr><td><b>Name</b></td><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>status</td><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>code</td><td>Status of the concept</td></tr><tr><td>deprecated</td><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>code</td><td>Version of HL7 in which the code was deprecated</td></tr><tr><td>V2 Concept Comment</td><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>string</td><td>V2 Concept Comment</td></tr><tr><td>V2 Concept Comment As Published</td><td>v2-concCommentAsPub</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub</td><td>string</td><td>V2 Concept Comment As Published</td></tr></table><p><b>Concepts</b></p><p>This case-sensitive code system <code>http://terminology.hl7.org/CodeSystem/v2-0174</code> defines the following codes in a Is-A hierarchy:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Concept Comment</b></td><td><b>V2 Concept Comment As Published</b></td><td><b>Deutsch (German, de)</b></td></tr><tr><td style=\"white-space:nowrap\">P<a name=\"v2-0174-P\"> </a></td><td>Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimen</td><td><div><p>Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimen</p>\n</div></td><td>can be associated with one or more OM4 (specimen) segments&lt;p&gt;See comment for value S</td><td>can be associated with one or more OM4 (specimen) segments&lt;p&gt;See comment for value S</td><td>Batterieanordnung</td></tr><tr><td style=\"white-space:nowrap\">F<a name=\"v2-0174-F\"> </a></td><td>Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens</td><td><div><p>Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens</p>\n</div></td><td>can be associated with one or more OM4 (specimen) segments&lt;p&gt;See comment for value S</td><td>can be associated with one or more OM4 (specimen) segments&lt;p&gt;See comment for value S</td><td>Funktionstest</td></tr><tr><td style=\"white-space:nowrap\">A<a name=\"v2-0174-A\"> </a></td><td>Atomic service/test/observation (test code or treatment code)</td><td><div><p>Atomic service/test/observation (test code or treatment code)</p>\n</div></td><td>can be associated with one or more OM4 (specimen) segments&lt;p&gt;a single direct observation and would usually be associated with an OM2 and/or OM3 segments</td><td>can be associated with one or more OM4 (specimen) segments&lt;p&gt;a single direct observation and would usually be associated with an OM2 and/or OM3 segments</td><td>Einzeluntersuchung</td></tr><tr><td style=\"white-space:nowrap\">S<a name=\"v2-0174-S\"> </a></td><td>Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes)&lt;p&gt;This set indicates that the code being described is used to order multiple service/test/observation b</td><td><div><p>Superset—a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes)\nThis set indicates that the code being described is used to order multiple service/test/observation batteries. For example, a client who routinely orders a CBC, a differential, and a thyroxine as an outpatient profile might use a single, special code to order all three test batteries, instead of having to submit three separate order codes.</p>\n</div></td><td>can be associated with one or more OM4 (specimen) segments\r\nCodes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&amp;Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observation</td><td>can be associated with one or more OM4 (specimen) segments\r\nCodes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&amp;Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observation</td><td>Latte von mehreren Batterieanforderungen (Aufnahmelatte)</td></tr><tr><td style=\"white-space:nowrap\">C<a name=\"v2-0174-C\"> </a></td><td>Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output)</td><td><div><p>Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output)</p>\n</div></td><td>can be associated with one or more OM4 (specimen) segments&lt;p&gt;a derived quantity and would usually be associated with an OM6 segment</td><td>can be associated with one or more OM4 (specimen) segments&lt;p&gt;a derived quantity and would usually be associated with an OM6 segment</td><td>Berechnetes Einzelergebnis</td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "inm"
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "oo"
    }
  ],
  "url" : "http://terminology.hl7.org/CodeSystem/v2-0174",
  "identifier" : [
    {
      "system" : "urn:ietf:rfc:3986",
      "value" : "urn:oid:2.16.840.1.113883.18.90"
    }
  ],
  "version" : "2.0.0",
  "name" : "NatureOfServiceTestObservation",
  "title" : "natureOfServiceTestObservation",
  "status" : "active",
  "experimental" : false,
  "date" : "2019-12-01",
  "publisher" : "Health Level Seven International",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://hl7.org"
        },
        {
          "system" : "email",
          "value" : "hq@HL7.org"
        }
      ]
    }
  ],
  "description" : "Code system of concepts specifying an identification of a test battery, an entire functional procedure or study, a single test value (observation), multiple test batteries or functional procedures as an orderable unit (profile), or a single test value (observation) calculated from other independent observations, typically used as an indicator for Master Files. Used in HL7 Version 2.x messaging in the OM1 segment.",
  "purpose" : "Underlying Master Code System for V2 table 0174 (Nature of Service/Test/Observation)",
  "copyright" : "This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html",
  "caseSensitive" : true,
  "valueSet" : "http://terminology.hl7.org/ValueSet/v2-0174",
  "hierarchyMeaning" : "is-a",
  "compositional" : false,
  "versionNeeded" : false,
  "content" : "complete",
  "property" : [
    {
      "code" : "status",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status",
      "description" : "Status of the concept",
      "type" : "code"
    },
    {
      "code" : "deprecated",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated",
      "description" : "Version of HL7 in which the code was deprecated",
      "type" : "code"
    },
    {
      "code" : "v2-concComment",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment",
      "description" : "V2 Concept Comment",
      "type" : "string"
    },
    {
      "code" : "v2-concCommentAsPub",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub",
      "description" : "V2 Concept Comment As Published",
      "type" : "string"
    }
  ],
  "concept" : [
    {
      "id" : "1822",
      "code" : "P",
      "display" : "Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimen",
      "definition" : "Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimen",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Batterieanordnung"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "can be associated with one or more OM4 (specimen) segments<p>See comment for value S"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "can be associated with one or more OM4 (specimen) segments<p>See comment for value S"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "1823",
      "code" : "F",
      "display" : "Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens",
      "definition" : "Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Funktionstest"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "can be associated with one or more OM4 (specimen) segments<p>See comment for value S"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "can be associated with one or more OM4 (specimen) segments<p>See comment for value S"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "1824",
      "code" : "A",
      "display" : "Atomic service/test/observation (test code or treatment code)",
      "definition" : "Atomic service/test/observation (test code or treatment code)",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Einzeluntersuchung"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "can be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segments"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "can be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segments"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "1825",
      "code" : "S",
      "display" : "Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes)<p>This set indicates that the code being described is used to order multiple service/test/observation b",
      "definition" : "Superset—a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes)\r\nThis set indicates that the code being described is used to order multiple service/test/observation batteries. For example, a client who routinely orders a CBC, a differential, and a thyroxine as an outpatient profile might use a single, special code to order all three test batteries, instead of having to submit three separate order codes.",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Latte von mehreren Batterieanforderungen (Aufnahmelatte)"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "can be associated with one or more OM4 (specimen) segments\r\nCodes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observation"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "can be associated with one or more OM4 (specimen) segments\r\nCodes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observation"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "1826",
      "code" : "C",
      "display" : "Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output)",
      "definition" : "Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output)",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Berechnetes Einzelergebnis"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "can be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segment"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "can be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segment"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    }
  ]
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.